******************************************************************************** Product brand: Secomea Version: 11.4.624384020 Release type: Release ******************************************************************************** ================================================================================ SiteManager and SiteManager Embedded ================================================================================ -------------------------------------------------- New features and enhancements: -------------------------------------------------- RD-6758: MQTT dataserver for DCM. A new generic MQTT dataserver for DCM has been added to SM and SM-E. This allows DCM to publish data to any generic MQTT broker. RD-6884: Bitwise operators in DCM aggregation engine. The following bitwise operations have been added to DCM's aggregation functionality: - bitwise and - bitwise or - bitwise xor - bitwise shift right - bitwise shift left - bitwise not RD-6961: New corporate visual identity (CVI) to GM, LM and SM web UI. Logos and images updated for Secomea's new Corporate Visual Identity. RD-7010: Add option to specify MQTT clientid for DCM MQTT collector. The DCM MQTT collector has added the option to specify MQTT clientid in the JSON configuration. -------------------------------------------------- Bug fixes: -------------------------------------------------- RD-6645: LogTunnel does not re-connect. If an application was continuously sending UDP packets through a LogTunnel while the SM was booting, the LogTunnel agent would fail to forward packets through the LogTunnel when the boot stage was finished. The application would have to pause sending for at least 30 seconds before the LogTunnel would recover. This has been fixed. RD-6928: RDP issue with pre-configured username/password that contains special characters. GTA to agents configured with non-ASCII characters in the password would fail. This has been fixed (by either SM or GM firmware upgrade). RD-7008: Unreliable multicast forwarding. On SiteManager models with 3 DEV ports, multicast frames did not reliably reach all subscribers, including those connected via Layer2 agents. The root cause is broken IGMP snooping in the Linux kernel driver for the integrated switch. Until that gets fixed upstream, IGMP snooping has been disabled so multicast will work. RD-7019: DNS resolution failure on VxWorks. SME for VxWorks failed to use the result of ordinary DNS resolution, but would go on to perform name resolution using Secomea's GM-DNS service. This has been fixed. -------------------------------------------------- Security advisories: -------------------------------------------------- - -------------------------------------------------------------------------------- Upgrade instructions can be found here: https://kb.secomea.com/docs/en/upgrade-sitemanager-firmware -------------------------------------------------------------------------------- ================================================================================ LinkManager Windows Client ================================================================================ -------------------------------------------------- New features and enhancements: -------------------------------------------------- RD-6961: New corporate visual identity (CVI) to GM, LM and SM web UI. Logos and images updated for Secomea's new Corporate Visual Identity. -------------------------------------------------- Bug fixes: -------------------------------------------------- - -------------------------------------------------- Security advisories: -------------------------------------------------- - -------------------------------------------------------------------------------- Upgrade instructions can be found here: https://kb.secomea.com/docs/en/upgrading-linkmanager-to-the-newest-version -------------------------------------------------------------------------------- ******************************************************************************** End ********************************************************************************